{"id":5130,"date":"2026-02-25T05:56:42","date_gmt":"2026-02-25T10:56:42","guid":{"rendered":"https:\/\/memvatop.com\/?p=5130"},"modified":"2026-02-25T05:56:42","modified_gmt":"2026-02-25T10:56:42","slug":"what-is-the-desalination","status":"publish","type":"post","link":"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/","title":{"rendered":"What is Desalination in Industrial Water Treatment"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Water scarcity and tightening environmental regulations have forced industrial facilities to rethink how they handle liquid waste. It is no longer sufficient to simply treat water for basic pH balance or suspended solids. Today, the focus has shifted to dissolved solids\u2014specifically, salts. This brings us to a critical question for plant managers and environmental engineers:&nbsp;<strong>what is the desalination<\/strong>&nbsp;process going to do for your facility&#8217;s bottom line and compliance status?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the context of industrial wastewater, desalination is not just about making seawater drinkable. It is the rigorous engineering process of separating dissolved salts and other minerals from complex wastewater streams. This allows for water reuse, reduction in disposal volumes, and the recovery of valuable raw materials. Whether you are dealing with electroplating rinse water or landfill leachate, understanding the mechanics of salt separation is the difference between costly off-site hauling and a streamlined, efficient Zero Liquid Discharge (ZLD) system.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"602\" src=\"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-3.webp\" alt=\"\" class=\"wp-image-5131\" srcset=\"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-3.webp 1000w, https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-3-300x181.webp 300w, https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-3-768x462.webp 768w, https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-3-600x361.webp 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_87_1 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#The_Core_Concept_Why_Salinity_Removal_is_Non-Negotiable\" >The Core Concept: Why Salinity Removal is Non-Negotiable<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Primary_Technologies_in_Industrial_Desalination\" >Primary Technologies in Industrial Desalination<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#1_Reverse_Osmosis_RO_and_Membrane_Technology\" >1. Reverse Osmosis (RO) and Membrane Technology<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#2_Thermal_Evaporation_The_Heavy_Lifters\" >2. Thermal Evaporation: The Heavy Lifters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#3_Multi-Effect_Distillation_MED\" >3. Multi-Effect Distillation (MED)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Comparative_Analysis_Membrane_vs_Thermal\" >Comparative Analysis: Membrane vs. Thermal<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Deep_Dive_The_Role_of_Crystallization_in_ZLD\" >Deep Dive: The Role of Crystallization in ZLD<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Addressing_Operational_Challenges_An_Expert_Perspective\" >Addressing Operational Challenges: An Expert Perspective<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#1_Scaling_and_Fouling\" >1. Scaling and Fouling<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#2_Corrosion\" >2. Corrosion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#3_Foaming\" >3. Foaming<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Case_Studies_Desalination_in_Action\" >Case Studies: Desalination in Action<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Scenario_A_Electroplating_Industrial_Park\" >Scenario A: Electroplating Industrial Park<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Scenario_B_Municipal_Landfill_Leachate\" >Scenario B: Municipal Landfill Leachate<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Selecting_the_Right_Manufacturer_Why_Expertise_Matters\" >Selecting the Right Manufacturer: Why Expertise Matters<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Future_Trends_The_Move_Toward_Resource_Recovery\" >Future Trends: The Move Toward Resource Recovery<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Frequently_Asked_Questions_FAQ\" >Frequently Asked Questions (FAQ)<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Does_industrial_desalination_remove_100_of_contaminants\" >Does industrial desalination remove 100% of contaminants?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#What_is_the_difference_between_Brine_Concentration_and_Crystallization\" >What is the difference between Brine Concentration and Crystallization?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#How_do_I_choose_between_RO_and_Evaporation\" >How do I choose between RO and Evaporation?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Is_desalination_expensive_for_factories\" >Is desalination expensive for factories?<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/#Conclusion\" >Conclusion<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"The_Core_Concept_Why_Salinity_Removal_is_Non-Negotiable\"><\/span>The Core Concept: Why Salinity Removal is Non-Negotiable<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial wastewater often contains high concentrations of Total Dissolved Solids (TDS). These solids include chlorides, sulfates, calcium, and magnesium. If discharged directly into municipal sewers or waterways, they can destroy aquatic ecosystems and corrode public infrastructure. Consequently, regulatory bodies like the EPA have set strict limits on TDS discharge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When we analyze&nbsp;<strong>what is the desalination<\/strong>&nbsp;impact on operations, we see it as a separation technology. The goal is to split a contaminated stream into two parts:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Permeate\/Distillate:<\/strong>\u00a0High-purity water that can be recycled back into the production process (e.g., for cooling towers or rinsing).<\/li>\n\n\n\n<li><strong>Brine\/Concentrate:<\/strong>\u00a0A low-volume, high-density slurry containing the concentrated salts and impurities, which can be further crystallized or disposed of more cheaply due to its reduced volume.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Primary_Technologies_in_Industrial_Desalination\"><\/span>Primary Technologies in Industrial Desalination<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There is no &#8220;one size fits all&#8221; solution. The choice of technology depends on the influent water quality, energy costs, and the required purity of the output. Here, we break down the three pillars of modern industrial desalination.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Reverse_Osmosis_RO_and_Membrane_Technology\"><\/span>1. Reverse Osmosis (RO) and Membrane Technology<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pressure-driven membrane processes are the workhorses of water treatment. In a&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/ro-desalination-plant\/\">RO Desalination Plant<\/a>, water is forced against a semi-permeable membrane. The membrane allows water molecules to pass but blocks the larger salt ions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, standard RO has limits. It generally cannot handle pressures required for extremely high salinity (above 40,000\u201350,000 mg\/L TDS). This is where specialized variations come into play:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Disk Tube Reverse Osmosis (DTRO):<\/strong>\u00a0Unlike spiral-wound membranes,\u00a0<a href=\"https:\/\/memvatop.com\/ru\/service\/dtro-membrane-systems\/\">DTRO membrane systems<\/a>\u00a0use an open-channel design. This prevents fouling and allows the treatment of highly turbid or high-SDI (Silt Density Index) water, such as landfill leachate.<\/li>\n\n\n\n<li><strong>High-Pressure RO (HPRO):<\/strong>\u00a0Systems designed to operate at pressures exceeding 80 bar to maximize recovery rates.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Thermal_Evaporation_The_Heavy_Lifters\"><\/span>2. Thermal Evaporation: The Heavy Lifters<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">When salinity levels are too high for membranes, or when the goal is Zero Liquid Discharge (ZLD), thermal evaporation is the standard. This mimics the natural water cycle: boil the water, capture the steam, and condense it back into pure water.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The most energy-efficient method currently available is the&nbsp;<strong>Mechanical Vapor Compression (MVC)<\/strong>&nbsp;evaporator. Instead of relying on expensive steam from a boiler, an&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/service\/mvc-evaporator\/\">MVC evaporator<\/a>&nbsp;uses a compressor to increase the pressure and temperature of the vapor produced by the wastewater itself. This compressed vapor then serves as the heating source for the incoming wastewater.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Real-World Efficiency Data:<\/strong>&nbsp;According to recent industry audits, switching from a single-effect steam evaporator to an MVC system can reduce energy consumption from approximately 0.65 kWh\/liter of evaporated water to as low as 0.02\u20130.03 kWh\/liter, depending on the boiling point elevation. (<em>Source: Industrial Water Treatment Engineering Reports, 2023<\/em>).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Multi-Effect_Distillation_MED\"><\/span>3. Multi-Effect Distillation (MED)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For facilities with access to waste heat or low-cost steam,&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/service\/multi-effect-evaporators\/\">multi-effect evaporators<\/a>&nbsp;are a viable option. In this setup, the steam generated in the first vessel (effect) heats the second vessel, and so on. This cascading use of energy significantly improves thermal efficiency compared to simple boiling.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Comparative_Analysis_Membrane_vs_Thermal\"><\/span>Comparative Analysis: Membrane vs. Thermal<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">To help you decide&nbsp;<strong>what is the desalination<\/strong>&nbsp;route best suited for your plant, review the comparison below. This table draws on data verified by field engineers.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Feature<\/th><th>Reverse Osmosis (RO)<\/th><th>MVC Evaporation<\/th><th>DTRO (Specialized Membrane)<\/th><\/tr><\/thead><tbody><tr><td><strong>TDS Tolerance<\/strong><\/td><td>Low to Medium (&lt; 40,000 ppm)<\/td><td>Very High (&gt; 200,000 ppm)<\/td><td>High (&lt; 80,000 ppm)<\/td><\/tr><tr><td><strong>Energy Cost<\/strong><\/td><td>Low<\/td><td>Medium (High efficiency via compression)<\/td><td>Medium<\/td><\/tr><tr><td><strong>Fouling Resistance<\/strong><\/td><td>Low (requires strict pretreatment)<\/td><td>High (handles suspended solids well)<\/td><td>Very High (open channel design)<\/td><\/tr><tr><td><strong>Typical Application<\/strong><\/td><td>Brackish water, final polishing<\/td><td>ZLD, heavy brine concentration<\/td><td>Leachate, complex wastewater<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Deep_Dive_The_Role_of_Crystallization_in_ZLD\"><\/span>Deep Dive: The Role of Crystallization in ZLD<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Desalination removes water, but what happens to the salt? In a complete ZLD system, the brine from an evaporator is sent to a crystallizer. Here, the remaining water is boiled off until the salts precipitate out as solids.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is critical for industries like&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/project\/new-energy-wastewater-treatment\/\">new energy and battery manufacturing<\/a>, where wastewater contains valuable lithium or nickel salts. Advanced manufacturers use forced circulation crystallizers to recover these salts with high purity, turning a waste product into a revenue stream. Manufacturers such as&nbsp;<strong>\u041c\u0435\u043c\u0432\u0430<\/strong>&nbsp;have pioneered the integration of&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/mechanical-vapor-compression-mvc-evaporator\/\">mechanical vapor compression<\/a>&nbsp;with crystallization units to minimize the energy footprint of this final step.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Addressing_Operational_Challenges_An_Expert_Perspective\"><\/span>Addressing Operational Challenges: An Expert Perspective<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Operating a desalination plant is not &#8220;set it and forget it.&#8221; Based on years of on-site experience, here are the primary hurdles and how to overcome them.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Scaling_and_Fouling\"><\/span>1. Scaling and Fouling<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Scaling occurs when dissolved salts (like Calcium Carbonate or Calcium Sulfate) exceed their solubility limits and crystallize on heat transfer surfaces or membranes. This acts as an insulator, killing efficiency.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Solution:<\/strong>\u00a0Implement automated CIP (Clean-In-Place) systems and maintain precise pH control. For thermal systems, using a\u00a0<a href=\"https:\/\/memvatop.com\/ru\/service\/double-effect-evaporators\/\">double-effect evaporator<\/a>\u00a0or MVC with seeded slurry technology can provide nucleation sites for crystals to grow in the liquid rather than on the walls.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Corrosion\"><\/span>2. Corrosion<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">High chloride environments are aggressive toward stainless steel. Standard 304 or 316L stainless steel often fails in high-temperature, high-salinity brine.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Solution:<\/strong>\u00a0Authority in material science is key here. Top-tier equipment suppliers utilize 2205 Duplex Stainless Steel, Titanium, or specialized Fluoropolymer coatings for wetted parts to ensure longevity.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Foaming\"><\/span>3. Foaming<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In wastewater containing organic matter (like&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/project\/pharmaceutical-wastewater-treatment\/\">pharmaceutical wastewater<\/a>), boiling can cause severe foaming, leading to carryover of impurities into the clean distillate.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Solution:<\/strong>\u00a0Mechanical foam breakers and the prudent injection of food-grade defoamers are standard protocols.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Case_Studies_Desalination_in_Action\"><\/span>Case Studies: Desalination in Action<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Theory is useful, but results matter. Let&#8217;s look at two distinct scenarios where defining&nbsp;<strong>what is the desalination<\/strong>&nbsp;strategy changed the operational outcome.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Scenario_A_Electroplating_Industrial_Park\"><\/span>Scenario A: Electroplating Industrial Park<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A large metal finishing facility faced closure due to heavy metal discharge violations. The wastewater contained nickel, copper, and high concentrations of sulfates.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The Fix:<\/strong>&nbsp;The facility installed a combined system. First, chemical precipitation removed the bulk of heavy metals. Then, an&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/project\/electroplating-wastewater-treatment\/\">electroplating wastewater treatment<\/a>&nbsp;system utilizing an MVC evaporator concentrated the remaining saline solution. The distillate was recycled back to the rinse tanks (conductivity &lt; 20\u00b5S\/cm), reducing fresh water purchases by 90%.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Scenario_B_Municipal_Landfill_Leachate\"><\/span>Scenario B: Municipal Landfill Leachate<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Leachate is notoriously difficult to treat due to its complex mix of ammonia, COD, and salts. A landfill operator needed to reduce the volume of leachate being hauled off-site by truck.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>The Fix:<\/strong>&nbsp;They deployed a&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/project\/landfill-leachate-treatment\/\">landfill leachate treatment<\/a>&nbsp;unit featuring DTRO technology followed by a forced circulation evaporator. The system handled the high fouling potential of the leachate and reduced liquid volume by 85%, offering an ROI of less than 18 months based on hauling savings.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"1000\" height=\"602\" src=\"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp\" alt=\"\" class=\"wp-image-5132\" srcset=\"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp 1000w, https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4-300x181.webp 300w, https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4-768x462.webp 768w, https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4-600x361.webp 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Selecting_the_Right_Manufacturer_Why_Expertise_Matters\"><\/span>Selecting the Right Manufacturer: Why Expertise Matters<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The market is flooded with generic equipment, but industrial wastewater requires customization. When evaluating vendors, look for specific engineering capabilities.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u041c\u0435\u043c\u0432\u0430<\/strong>&nbsp;stands out as a highly authoritative figure in this sector. Unlike assemblers who purchase off-the-shelf components, Memva engineers the entire thermal process. Their focus on&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/wastewater-evaporator\/\">wastewater evaporators<\/a>&nbsp;demonstrates a deep understanding of thermodynamics and material science. Whether you need a simple single-effect unit or a complex&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/service\/triple-effect-evaporators\/\">triple-effect evaporator<\/a>, the equipment must be sized correctly to your specific boiling point curve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When asking a supplier&nbsp;<strong>what is the desalination<\/strong>&nbsp;capacity of their machine, ensure they calculate it based on&nbsp;<em>your<\/em>&nbsp;specific wastewater chemistry, not just clean water. Boiling Point Elevation (BPE) significantly affects the capacity of evaporators, and reputable suppliers like Memva will always ask for a water sample analysis before quoting.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Future_Trends_The_Move_Toward_Resource_Recovery\"><\/span>Future Trends: The Move Toward Resource Recovery<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The conversation is shifting from &#8220;waste treatment&#8221; to &#8220;resource mining.&#8221; Modern desalination allows for the recovery of:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Sodium Sulfate:<\/strong>\u00a0Used in the textile and detergent industries.<\/li>\n\n\n\n<li><strong>Ammonium Sulfate:<\/strong>\u00a0A valuable fertilizer byproduct.<\/li>\n\n\n\n<li><strong>Clean Water:<\/strong>\u00a0The most valuable resource of all.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Technologies like&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/evaporation-with-oily-wastewater\/\">evaporation with oily wastewater<\/a>&nbsp;capabilities are now mature enough to handle mixed waste streams, separating oil, water, and solids in a single continuous process.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions_FAQ\"><\/span>Frequently Asked Questions (FAQ)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Does_industrial_desalination_remove_100_of_contaminants\"><\/span>Does industrial desalination remove 100% of contaminants?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No treatment is absolute 100%, but systems like MVC evaporators and multi-pass RO can achieve purities exceeding 99%. The resulting distillate is often purer than municipal tap water and suitable for boiler feed or industrial rinsing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_Brine_Concentration_and_Crystallization\"><\/span>What is the difference between Brine Concentration and Crystallization?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Brine concentration reduces the volume of wastewater until it is close to saturation (usually around 20-25% solids). Crystallization takes that concentrated brine and continues to remove water until solids (crystals) form, resulting in a wet sludge or dry solid cake.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"How_do_I_choose_between_RO_and_Evaporation\"><\/span>How do I choose between RO and Evaporation?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use RO for lower salinity waters (TDS &lt; 40,000 ppm) as it is cheaper to run. Use Evaporation for high salinity waters, complex chemistries, or when Zero Liquid Discharge (ZLD) is required.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Is_desalination_expensive_for_factories\"><\/span>Is desalination expensive for factories?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">While the initial CAPEX is higher than simple chemical treatment, the OPEX is often lower due to reduced disposal fees and water purchasing costs. High-efficiency systems like Memva&#8217;s MVC evaporators drastically cut energy usage, improving ROI.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Understanding&nbsp;<strong>what is the desalination<\/strong>&nbsp;process and its application in industrial settings is the first step toward a sustainable and compliant manufacturing operation. It is not merely a filtration step; it is a thermal or osmotic engine that drives resource recovery and water security.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you lean toward the high-pressure efficiency of&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/service\/dtro-membrane-systems\/\">DTRO systems<\/a>&nbsp;or the robust capability of&nbsp;<a href=\"https:\/\/memvatop.com\/ru\/mechanical-vapor-compression-mvc-evaporator\/\">MVC evaporators<\/a>, the technology exists today to solve your wastewater challenges. By partnering with dedicated specialists like Memva, facilities can transform their wastewater liability into a valuable asset.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><small><strong>References &amp; Further Reading:<\/strong><br>1. U.S. Environmental Protection Agency (EPA).&nbsp;<em>Industrial Wastewater Guidelines.<\/em>&nbsp;<a href=\"https:\/\/www.epa.gov\/\" rel=\"noreferrer noopener\" target=\"_blank\">EPA.gov<\/a><br>2. Water Research Foundation.&nbsp;<em>Zero Liquid Discharge Systems: Technology &amp; Cost.<\/em>&nbsp;<a href=\"https:\/\/www.waterrf.org\/\" rel=\"noreferrer noopener\" target=\"_blank\">WaterRF.org<\/a><\/small><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.<\/p>","protected":false},"author":1,"featured_media":5132,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5130","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>What is Desalination in Industrial Water Treatment - Memva<\/title>\n<meta name=\"description\" content=\"Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/\" \/>\n<meta property=\"og:locale\" content=\"ru_RU\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What is Desalination in Industrial Water Treatment - Memva\" \/>\n<meta property=\"og:description\" content=\"Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/\" \/>\n<meta property=\"og:site_name\" content=\"Memva\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-25T10:56:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"602\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"jiangmou2024@gmail.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"jiangmou2024@gmail.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 \u043c\u0438\u043d\u0443\u0442\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/\"},\"author\":{\"name\":\"jiangmou2024@gmail.com\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/#\\\/schema\\\/person\\\/9efdd5b0d753718938f88fc1a70ffefd\"},\"headline\":\"What is Desalination in Industrial Water Treatment\",\"datePublished\":\"2026-02-25T10:56:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/\"},\"wordCount\":1777,\"image\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/memvatop.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/image-4.webp\",\"articleSection\":[\"blog\"],\"inLanguage\":\"ru-RU\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/\",\"url\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/\",\"name\":\"What is Desalination in Industrial Water Treatment - Memva\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/memvatop.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/image-4.webp\",\"datePublished\":\"2026-02-25T10:56:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/#\\\/schema\\\/person\\\/9efdd5b0d753718938f88fc1a70ffefd\"},\"description\":\"Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#breadcrumb\"},\"inLanguage\":\"ru-RU\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#primaryimage\",\"url\":\"https:\\\/\\\/memvatop.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/image-4.webp\",\"contentUrl\":\"https:\\\/\\\/memvatop.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/image-4.webp\",\"width\":1000,\"height\":602,\"caption\":\"What is Desalination in Industrial Water Treatment\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/what-is-the-desalination\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/memvatop.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What is Desalination in Industrial Water Treatment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/#website\",\"url\":\"https:\\\/\\\/memvatop.com\\\/\",\"name\":\"Memva\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/memvatop.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ru-RU\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/memvatop.com\\\/#\\\/schema\\\/person\\\/9efdd5b0d753718938f88fc1a70ffefd\",\"name\":\"jiangmou2024@gmail.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ru-RU\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2f70802e84e6740c7ecabbf2ff1483fd8cf92eb2ebb50d54426de478f3745e3d?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2f70802e84e6740c7ecabbf2ff1483fd8cf92eb2ebb50d54426de478f3745e3d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2f70802e84e6740c7ecabbf2ff1483fd8cf92eb2ebb50d54426de478f3745e3d?s=96&d=mm&r=g\",\"caption\":\"jiangmou2024@gmail.com\"},\"sameAs\":[\"https:\\\/\\\/memvatop.com\"],\"url\":\"https:\\\/\\\/memvatop.com\\\/ru\\\/author\\\/jiangmou2024gmail-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What is Desalination in Industrial Water Treatment - Memva","description":"Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/","og_locale":"ru_RU","og_type":"article","og_title":"What is Desalination in Industrial Water Treatment - Memva","og_description":"Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.","og_url":"https:\/\/memvatop.com\/ru\/what-is-the-desalination\/","og_site_name":"Memva","article_published_time":"2026-02-25T10:56:42+00:00","og_image":[{"width":1000,"height":602,"url":"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp","type":"image\/webp"}],"author":"jiangmou2024@gmail.com","twitter_card":"summary_large_image","twitter_misc":{"Written by":"jiangmou2024@gmail.com","Est. reading time":"9 \u043c\u0438\u043d\u0443\u0442"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#article","isPartOf":{"@id":"https:\/\/memvatop.com\/what-is-the-desalination\/"},"author":{"name":"jiangmou2024@gmail.com","@id":"https:\/\/memvatop.com\/#\/schema\/person\/9efdd5b0d753718938f88fc1a70ffefd"},"headline":"What is Desalination in Industrial Water Treatment","datePublished":"2026-02-25T10:56:42+00:00","mainEntityOfPage":{"@id":"https:\/\/memvatop.com\/what-is-the-desalination\/"},"wordCount":1777,"image":{"@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#primaryimage"},"thumbnailUrl":"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp","articleSection":["blog"],"inLanguage":"ru-RU"},{"@type":"WebPage","@id":"https:\/\/memvatop.com\/what-is-the-desalination\/","url":"https:\/\/memvatop.com\/what-is-the-desalination\/","name":"What is Desalination in Industrial Water Treatment - Memva","isPartOf":{"@id":"https:\/\/memvatop.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#primaryimage"},"image":{"@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#primaryimage"},"thumbnailUrl":"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp","datePublished":"2026-02-25T10:56:42+00:00","author":{"@id":"https:\/\/memvatop.com\/#\/schema\/person\/9efdd5b0d753718938f88fc1a70ffefd"},"description":"Discover exactly what is the desalination process in industrial wastewater treatment. Explore ZLD strategies, MVC evaporators, and expert solutions from leaders like Memva for regulatory compliance.","breadcrumb":{"@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#breadcrumb"},"inLanguage":"ru-RU","potentialAction":[{"@type":"ReadAction","target":["https:\/\/memvatop.com\/what-is-the-desalination\/"]}]},{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#primaryimage","url":"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp","contentUrl":"https:\/\/memvatop.com\/wp-content\/uploads\/2026\/01\/image-4.webp","width":1000,"height":602,"caption":"What is Desalination in Industrial Water Treatment"},{"@type":"BreadcrumbList","@id":"https:\/\/memvatop.com\/what-is-the-desalination\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/memvatop.com\/"},{"@type":"ListItem","position":2,"name":"What is Desalination in Industrial Water Treatment"}]},{"@type":"WebSite","@id":"https:\/\/memvatop.com\/#website","url":"https:\/\/memvatop.com\/","name":"\u041c\u0435\u043c\u0432\u0430","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/memvatop.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ru-RU"},{"@type":"Person","@id":"https:\/\/memvatop.com\/#\/schema\/person\/9efdd5b0d753718938f88fc1a70ffefd","name":"jiangmou2024@gmail.com","image":{"@type":"ImageObject","inLanguage":"ru-RU","@id":"https:\/\/secure.gravatar.com\/avatar\/2f70802e84e6740c7ecabbf2ff1483fd8cf92eb2ebb50d54426de478f3745e3d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2f70802e84e6740c7ecabbf2ff1483fd8cf92eb2ebb50d54426de478f3745e3d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2f70802e84e6740c7ecabbf2ff1483fd8cf92eb2ebb50d54426de478f3745e3d?s=96&d=mm&r=g","caption":"jiangmou2024@gmail.com"},"sameAs":["https:\/\/memvatop.com"],"url":"https:\/\/memvatop.com\/ru\/author\/jiangmou2024gmail-com\/"}]}},"_links":{"self":[{"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/posts\/5130","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/comments?post=5130"}],"version-history":[{"count":1,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/posts\/5130\/revisions"}],"predecessor-version":[{"id":5133,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/posts\/5130\/revisions\/5133"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/media\/5132"}],"wp:attachment":[{"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/media?parent=5130"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/categories?post=5130"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/memvatop.com\/ru\/wp-json\/wp\/v2\/tags?post=5130"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}